Back

HSE-Small Operating Table size 1, Type 872/3

for mouse and rat pup

The HSE-Operating Table size 1 is suitable for mice and rat pus. At a heavy cast iron tripod base is mounted a ball joint, allowing to tilt the plate in any direction. The plate of the operating table measures 160 mm × 100 mm and is made of plastic coated aluminium plate. Both sides of the plate have multiple slots for fixing the paw holderss and optional thorax retractors. Numerous slots and dedicated paw holders allow both large and small animals to be held firmly in position for optimal surgical access. A block clamp with ball joint holder can be fixed onto the plate for holding various probes, electrodes, or cannulae. For grounding the table e.g. while recording the animals ECG, there is a socket for connecting a banana plug (4 mm).
The operating table comes with paw holders and grounding cable.

The operating table size 1 is available in four versions:

  • Operating table size 1 Type 872/3(Tor F) without heating.
    This model is recommended only for removing isolated organs and tissue and not suitable for longer experiments at anaesthetized animals.
    NOTE: The heating system cannot be retrofitted.
  • Operating table size 1H Type 872/3H(Tor F) with built-in heating, uncontrolled, including a heating adapter box and a power supply.
    In this version the table reaches a fixed temperature of approx. 38°C. This model is suitable for short term surgery or experiments
    NOTE: The temperature of the table is not controlled.
  • Operating table size 1H Type 872/3H(Tor F) with built-in heating, temperature controlled, including heating controller Type 872/1.
    This arrangement is recommended for short-term experiments. Good stabilization of the temperature of the table is ensured, using the temperature probe which is built-in the table. The table is heated and maintained at stable temperature by controlling the amount of DC-energy to the heating element. On the controller the energy is adjustable in a range of 20-100% of the maximum energy.
    NOTE: The temperature of the table is controlled.
  • Operating table size 1H Type 872/3H(Tor F) with built-in heating, temperature controlled, including adapter box and homeothermic controller 872/2
    This arrangement is recommended for long-time experiments. Good stabilization of the temperature of the table is ensured, using a rectal temperature probe, the temperature of the animals body can directly be controlled which is the best way to operate.
    NOTE: The temperature of the animal is controlled.

T = Tripod Version -- F = Flat Version

     

Op-table size 1HT with adapter and power supply

Op-table size 1HT with heating controller

Op-table size 1HT with homeothermic controller

 

Base

Non-Heated

Heated with Power Supply
115 V - 230 V

Heated with Heating Controller 115V

Heated with Heating Controller 230V

Heated with Homeothermic Controller 115V

Heated with Homeothermic Controller 230V

Tripod

73-3754  73-3774  73-3770  73-3771 73-3778  73-3779 

Flat Angled

73-3768  73-3775  73-3772  73-3773  73-3780  73-3781


HSE-Small Operating Table size 5, Type 872

for rodents (rat, guinea-pig)

   

The HSE-Operating Table size 5 is suitable for rodents (rat, guinea-pig. At a heavy cast iron tripod base is mounted a ball joint, allowing to tilt the plate in any direction. The plate of the operating table measures 300 mm × 195 mm and is made of plastic coated aluminium plate. Both sides of the plate have multiple slots for fixing the paw holderss and optional thorax retractors. Numerous slots and dedicated paw holders allow both large and small animals to be held firmly in position for optimal surgical access. A block clamp with ball joint holder can be fixed onto the plate for holding various probes, electrodes, or cannulae. For grounding the table e.g. while recording the animals ECG, there is a socket for connecting a banana plug (4 mm).
The operating table comes with paw holders and grounding cable.

The operating table size 5 is available in four versions:

  • Operating table size 5 Type 872(T or F) without heating.
    This model is recommended only for removing isolated organs and tissue and not suitable for longer experiments at anaesthetized animals.
    NOTE: The heating system cannot be retrofitted.
  • Operating table size 5H Type 872H(T or F) with built-in heating, uncontrolled, including a heating adapter box and a power supply.
    In this version the table reaches a fixed temperature of approx. 38°C. This model is suitable for short term surgery or experiments
    NOTE: The temperature of the table is not controlled.
  • Operating table size 5H Type 872H(T or F) with built-in heating, temperature controlled, including heating controller Type 872/1.
    This arrangement is recommended for short-term experiments. Good stabilization of the temperature of the table is ensured, using the temperature probe which is built-in the table. The table is heated and maintained at stable temperature by controlling the amount of DC-energy to the heating element. On the controller the energy is adjustable in a range of 20-100% of the maximum energy.
    NOTE: The temperature of the table is controlled.
  • Operating table size 5H Type 872H(T or F) with built-in heating, temperature controlled, including adapter box and homeothermic controller 872/2
    This arrangement is recommended for long-time experiments. Good stabilization of the temperature of the table is ensured, using a rectal temperature probe, the temperature of the animals body can directly be controlled which is the best way to operate.
    NOTE: The temperature of the animal is controlled.

T = Tripod Version -- F = Flat Version

     

Op-table size 5HT with adapter and power supply 

Op-table size 5HT with heating controller

Op-table size 5HT with homeothermic controller  

Base

Non-Heated

Heated with Power Supply
115 V - 230 V

Heated with Heating Controller 115V

Heated with Heating Controller 230V

Heated with Homeothermic Controller 115V

Heated with Homeothermic Controller 230V

Tripod

73-3529 73-3776  73-3584 73-3582 73-3782  73-3783

Flat Angled

73-3530  73-3777 73-3586 73-3585 73-3784  73-3785


Heating adapter box Type 872/4 with power supply to HSE-Small Operating Table size 1 and size 5

The adapter consists of a separate box including the permanent control of the operating table temperature. It controls the table temperature via the temperature sensor built-in the operating table. The temperature of the operating table is fixed to 38°C°.
TECHNICAL DATA

Power Output  12 V DC / 60 VA 
Mains Voltage  115 V/60 Hz - 230 VAC/50 Hz
Dimensions  Adapter box 105 x 55 x 30 mm (4.1 x 2.2 x 1.5 in)
Power supply 140 x 60 x 30 mm (5.5 x 2.4 x 1.5 in)
Weight  0.6 kg  (1.3 lb)


Heating Controller Type 872/1 to HSE-Small Operating Table size 1 and size 5

The adjustable temperature heated models use the heating controller 872/1. In this version, there is no feedback control. The table is heated and maintained at stable temperature by controlling the amount of DC-energy to the heating element. On the controller the energy is adjustable in a range of 20-100% of the maximum energy. The controller also ensures the safety shutoff. These models are often used for quick surgical procedures or acute animal studies (30 minutes
or less) requiring the core temperature of the animal be maintained. To adjust the controller an electronic thermometer for measuring the animal body temperature is required.
TECHNICAL DATA

Power Output  DC 9 Volt, 40 VA adjustable in the range 20 - 100% 
Mains Voltage  230 VAC/50 Hz Version, or 115 VAC/60 Hz Version 
Dimensions  125 x 95 x 210mm (4.9 x 3.8 x 8.3 in) 
Weight  2 kg (4.4 lb) 


Homeothermic Controller Type 872/2 to HSE-Small Operating Table size 1 and size 5

Should the animal’s core temperature fall, power is automatically increased to the operating table; conversely, power will automatically reduce if the animal’s temperature rises. During this process the animal’s temperature is continuously displayed on a front panel LCD display.

This homeothermic controller consists of three parts: a probe, a control unit, and a adapter box. The flexible probe is a precision thermistor encapsulated in a bead of epoxy resin at the top of a flexible hollow plastic tube. The 2 mm diameter probe is 100 mm (4 in) long and has a 2 m (6 ft) long cable with plug for attachment to the control unit. It is suitable for a wide range of laboratory animals from adult mice to rata and guinea pigs

The rigid probe is a stainless steel shaft with a diameter of 1.6 mm. The shaft attaches to a 2 m (6 ft) cable with a plug that connects to the control unit. It is suitable for use with mice,and rodents. The output of the temperature sensing probe is used by the control unit to proportionally control the regulated, low-voltage DC supply to the operating table. This method of control alleviates the interference problems associated with that of non-proportional control, such as switching contacts, thus enabling the system to be used in conjunction with highgain recording systems.

The control temperature is preset at 37°C (98.6°F) at the factory, but can be adjusted within the range of 35° to 40°C (95° to 104°F) by means of a control on the front panel. An LCD display on the control unit continuously displays the probe temperature. A horizontal LED bar graph indicates the level of power being delivered to the operating table. When core temperature is substantially below the desired temperature the bar graph will indicate maximum power being delivered.

The adapter consists of a separate box including the permanent control of the maximum temperature of the operating table. It acts as a safety cicuit by limiting the maximum temperature of the operating table to 40°C. This circuit uses a second thermistor probe built-in the operating table.

The operating table is electrically floating, with respect to ground however, one end of the heating element can be grounded by a switch on the front panel of the control unit. The system operates satisfactorily whether or not the operating table is grounded. Special circuitry eliminates electrical noise thus permitting sensitive recordings.

TECHNICAL DATA 

Power Output  Maximum 40 VA. Supplied continously (not switched), the level is dependent on the temperature monitored
Ripple Output  Less than 10mV RMS 
Temperature accuracy   +/- 1% of actual temperature (35°C to 40°C)
Temperature range  35°C to 40°C monitored on the front panel LCD 
Temperature Safety limit  40 °C
Analogue Output  50 mV at 35°C to 150 mV at 40°C (20 mv/°C) 
Mains Voltage  230 VAC/50 Hz Version, or 115 VAC/60 Hz Version 
Dimensions  274 x 320 x 94mm (10.8 x 12.6 x 3.7 in) (WxHxD)
Weight  3 kg (6.6 lb) 


Animal Operating Table No. 11 A

for Rabbits and Cats


The table-top can be electrically heated to a temperature of 30-32°C and is manufactured of stainless steel. Dimensions of the table-top 650 x 400 mm, the paws of the animals are fixed by means of strings. The telescopic feets allow to incline the table-top or to change the height.

Net-weight: 12 kg.


HUGO SACHS ELEKTRONIK-HARVARD APPARATUS GmbH
Gruenstrasse 1 · D-79232 March-Hugstetten · GERMANY
Phone: +49 (0) 76 65 - 92 00-0 · Fax: +49 (0) 76 65 - 92 00-90