The PHD Ultra is the solution for your most demanding fluidics applications. This pump represents the latest technology in syringe pumps and was developed utilizing the feedback of the world's largest populations of syringe pump users.
The PHD Ultra will change the way you think about syringe pumps. There are three major areas which make the PHD Ultra the new standard for syringe pumps:
1. New - Patent pending mechanical drive mechanism and syringe holding mechanics to achieve the highest performance of any syringe pump
2. New - EZ PRO Software and user
interface allow easy programming of methods from simple to complex,
all without the use of a PC
- Preprogrammed methods for simple to complex operations that
allow you to be up and running with the push of a button
- LCD, high resolution color touch screen for powerful functionality,
yet easy to use
3. New levels of versatility
a. Configurations: push-pull, standard, remote, high pressure,
multi racks
b. Connectivity: rs232 and USB for PC; RS 485 for daisy chain

Monitoring more straightforward than
ever
With a Samba Preclin transducer, intravascular blood pressure
(IBP) and left ventricular pressure (LVP) monitoring become more
straightforward
than ever. Inserted through the carotid or fermoral artery you
can receive accurate, highresolution data.
Pressure patterns never observed
before
The small size allows you to insert the sensor directly into the
brain tissue or in the brain ventricles and measure very rapid
trauma events. The extremely fast sampling rate and sensitivity
enable you to see pressure patterns never observed before.
Insensitive to all electro-magnetic
fields
Samba Preclin offers exciting opportunities when using MRI-scanners.
The sensor gives you total freedom to monitor pressure while simultaneously
capturing images in the latest high-end scanners. Gating also
becomes more reliable and robust with the Samba Preclin transducer.
If placed in the tail artery of a rat, both IBP and respiratory
signals can be captured using a single sensor.
Where to use Samba Preclin?
Preclinical research in the area of:
Heart and Circulation
Brain and Nervous System
Lungs and Breathing
Digestive System
Kidney and Urinary System
Reproduction System
Muscles
How to use Samba Preclin
The primary feature is the miniature size: 0.36 or 0.42 mm depending
on version. The transducer can be applied into a tiny organ or
tissue and smoothly inserted without causing unnecessary harm.
Once in place, the transducer will not affect the actual environment
it is set to measure.
The Samba Preclin transducer is also safe, meaning that no electricity
and no bio-hazardous materials are involved. It is also insensitive
to any form of electro-magnetic fields to make it fully compatible
with high-end imaging technologies such as MR, CT, PET and SPECT.
If scanner triggering is desired the blood pressure signal can
be used in favour of ECG to further increase image quality.
The Samba Preclin pressure transducer
comprises a silicon sensor element mounted on an optical fibre.
Each transducer is calibrated at the factory
before delivery to eliminate the need for customer calibration.
The calibration data is stored on a small EPROM positioned on
the connector and
is read automatically at start up.

The new Samba control unit is a compact, portable and battery operated unit equipped with internal memory for temporary data storage. The Samba 201 has one fiber optic port, while the Samba 202 is fitted with two ports, which allow for extended operations. The individual calibration data stored on the EPROM of each connected Samba transducer is automatically read by the control units to ensure exact measurements. The USB 2.0 data interface simplifies the data transmission to your computer and the 3.2 inch display performs sharp figures.


![]()