![]() |
This programmable stimulator module is intended for the stimulation
of isolated tissue, with operation from PC computer. |
|
|
The Programmable Stimulator Module PSM is a square-wave single-channel stimulator with isolated constant-current output for the PLUGSYS system. It has been developed specially for stimulating isolated tissue in physiological and pharmacological research. The stimulator is operated through software from a PC. All the settings are performed through the control program STIMULUS or through HSE-HA Software ACAD or ISOHEART. The system features interactive operation, i.e. all inputs are set at a special user level with window menus. The instrument settings are stored inside the computer on disk or hard disk and can at any time be loaded into the stimulator module using the control program. With automated experimental setups the stimulator can be controlled from evaluation HSE-HA software. For example, in automatically evaluating the refractory period of an isolated guinea-pig atrium, each stimulation cycle is followed by recalculation of the interval between the first and second stimulus of the twin stimulation, and the appropriate changes are then made to the settings of the stimulator module. The unit cannot be operated by itself; it requires at least the system components listed below.
| Construction | Programmable Stimulator Module PSM designed as module of HSE-HA PLUGSYS measuring system; occupies one slot unit |
| Hardware Required | Pentium computer, at least 500 MHz; HSE-HA PLUGSYS basic system case, Type 603; HSE-HA data acquisition hardware, PLUGSYS version; DIM-D Digital Bus Link for DIM |
| Software Required | Microsoft WINDOWS 2000/XP/NT; HSE-HA Stimulator Control Program Stimulus; HSE-HA software ACAD, ISOHEART, NEURODYN or EPES with according Software module |
| Operating Modes | Free-running (continuous stimulation); Trains; hardware-triggered through control signal; software-triggered through control command; single or twin stimulation; output current polarity fixed or alternating (automatic change-over after each stimulation cycle) |
| Basic Rhythm R | Continuously adjustable between 100 msec and 10 sec |
| Delay D | Spacing between stimulus 1 and stimulus 2 adjustable between 1 msec and 1 sec, or 0 for no twin stimulation |
| Width W | Stimulus duration adjustable between 0.5 msec and 200 msec |
| Output O | Output can be programmed from 1 mA to 25 mA or from 10 mA to 250 mA (manual change of current range) |
| Power Supply |
+ 5 V/700 mA and + 24 V/1 A through connector from PLUGSYS system bus Note: In case of using more than one PSM in the basic system case, an additional power supply must be installed (option 5, 24 V DC, 100 VA).A maximum of 4 PSM modules can be installed (power consumption 100 VA). |
| Dimensions, H x W x D | 128.7 x 20.2 x 220 mm (5.1 x 0.8 x 8.7 in) [1 PLUGSYS slot unit ] |
| Weight | 0.35 kg (0.8 lbs) |
![]()
HUGO SACHS ELEKTRONIK-HARVARD
APPARATUS GmbH
Gruenstrasse 1 · D-79232 March-Hugstetten · GERMANY
Phone: +49 (0) 76 65 - 92 00-0 · Fax: +49 (0) 76 65 - 92
00-90