Transducers for haemodynamic measurements

Pressure transducers for arterial and venous blood pressure measurement

APT300 Inexpensive Pressure Transducer

The APT300 transducer is an inexpensive pressure transducer which can be used to measure arterial blood pressures in all species, even on mice with a high heart rate.
It can be used for measurement of arterial pressure in vivo as well as for perfusion pressures in isolated perfused organs such as heart or kidney. It can also be used to measure isovolumetric left ventricular (using a balloon) pressures in isolated hearts from mice up to rabbits or pigs.
The transducer consists of a contact plate with cable and the exchangeable transducer head, which can easily be replaced. Contact plates with cables for different amplifier types are available.

  • Inexpensive
  • Reliable
  • Accurate
  • Low volume displacement
  • Suitable for virtually all arterial pressure applications
  • Easy to fill
  • Stopcocks included
  • Simple holder for rod mounting
Operating pressure: -300 to 300 mmHg
Overpressure:  4000 mmHg 
Sensitivity:  5 µV/V/mmHg (±1%) 
Excitation voltage:  2 – 15 V DC (or AC up to 5kHz)
Zero offset:   < 25 mmHg
Temperature coefficient zero offset:  < 0.2 mmHg / °C
Temperature coefficient of sensitivity:  < 0.1% / °C 
Operating temperature:  15 to 40°C 
Storage temperature:  –25 to 70°C 
Volume displacement:  < 0.04 mm 3/100 mmHg
Input impedance:  >500 Ohm 
Output impedance:  356 Ohm ±1%
Isolation against fluid:  > 5000 V
Natural frequency:  > 1 KHz
Cable length:  3 m 
Holder: 
 8mm rod length 75mm or 160mm


Bllod pressure transducer P23XL

Statham Pressure Transducer P23XL

The P23XL is a pressure transducer for arterial and venous blood pressure measurement. It can be connected to any strain gauge amplifer (DBA, TAM-A, TAM-D...) 

Pressure range –50 to +300 mmHg 
Maximum over-pressure  10,000 mmHg 
Sensitivity 5µV/V/mmHg ±1% 
Volume displacement  0.04 mm³/100 mmHg pressure 
Bridge resistance  350 ohms, nominal 
Non-linearity  ±1.5 mmHg over 0 to 300 mmHg 
hysteresis ±0.1 mmHg over 0 to 10 mmHg  
Zero balance ±25 mmHg 
Thermal coefficient of sensitivity (typical)  ±0.1%/°C 
Thermal coefficient of zero (typical) ±0.3 mmHg/°C 
Electrical leakage:   AC 2µA maximum at 115 V rms 60 Hz
DC 100 megohms minimum at 50 V DC
 
Insulation  Withstands 10,000 V DC 
Rated excitation voltage  7.5 V DC or AC up to 5 kHz 
Maximum excitation voltage  10 V DC or AC 