Back

Transducers for haemodynamic measurements

Scisense High-Fidelity Pressure-Volume Catheters

              
   

 High-Fidelity Pressure-Volume Catheters

  • High frequency response maintains signal integrity and prevents damping or attenuation of signal
  • No motion artifact or overshoot as with conventional fluid-filled catheters
  • 10µV/V/mmHg sensitivity provides higher measurement resolution than any other sensor on the market
  • Pressure membrane recessed for protection
  • Vented to atmosphere to correct for barometric pressure
  • Pressure and volume at the source from a single instrument


Polyimide Tubing

  • Provides ideal balance of flexibility and rigidity, ensuring easy insertion and maneuverability
  • Will not fray like many other catheter materials which, over time, will irritate vascular linings and valves
  • Small diameter of tubing minimizes impact on aortic flow resulting in more physiologic data Smooth Profile
  • Reduces potential damage to endothelial lining during catheterization
  • Allows for easy passage through aortic valve (can be inserted and withdrawn repeatedly)

Variable Segment Length (VSL) Catheters

  • Are ideal for use in isolated working heart studies where typical perfusion solutions (e.g. Krebs-Henseleit) will have resistivity
    different from that of blood
  • Have a series of conductance rings situated proximal to the pressure sensor
  • Have up to 4 different segment lengths (S1, S2, S3, S4) that can be placed on one catheter providing versatility when studying hearts of different sizes
  • VSL hardware allows for easy and quick selection of any one of the 4 segments on the catheter to be used for measuring volume VSL Pressure-Volume Control Box
  • For use with standard P-V and VSL catheters
  • Can be used with solutions of different conductivity to blood (e.g. Krebs-Henseleit)
  • Has adjustable gains and offset to be used with ANY conductive medium with various-sized rodent hearts
  • Analog output for compatibility with a range of data acquisition systems, see Section I Physiology for options
 
Pressure-Volume Catheter   
model number  Product  Application sensor size main catheter size (nominal) main catheter length (nominal)
72-9102 / FT112B Pressure-Volume Catheter Mouse  Mouse 1.2F  0.9F 45 cm (18 in)
72-9106 / FT212B Pressure-Volume Catheter Rat Rat 1.6F  1.6F 45 cm (18 in)
72-9110 / FT312B-SF-06 6 Electrode (3 Segment) Pressure-Volume Catheter  Rabbit 3F  2.7F 61 cm (24 in)
72-9138 / FT312B-(P/S) 3 Segment Pressure-Volume Catheter (Pigtail/Straight) Large Animal  3F  2.7F 61 cm (24 in)
72-9139 / FT512B-(P/S) 5 Segment Pressure-Volume Catheter (Pigtail/Straight) Large Animal  5F   4.7F  120 cm (48 in) 
72-9140 / FT712B-(P/S) 5 Segment Pressure-Volume Catheter (Pigtail/Straight) Large Animal   7F  6.4F  120 cm (48 in) 
 
Dual Pressure-Volume Catheter    
model number  Product  Application sensor size main catheter size (nominal) main catheter length (nominal)
72-9103 / FT114B Dual Pressure-Volume Catheter  Mouse 1.2F  0.9F 45 cm (18 in)
72-9107 / FT214B Dual Pressure-Volume Catheter Rat 1.9F  1.6F 45 cm (18 in)
72-9111 / FT314B-SF-06 6 Electrode (3 Segment) Dual Pressure-Volume Catheter  Rabbit 3F  2.7F 61 cm (24 in)
   
Variable Segment (VSL) Catheter   
model number  Product  Application sensor size main catheter size (nominal) main catheter length (nominal)
72-9112 FT212B-VSL-6/8/10/12 Rat VSL Pressure-Volume Catheter (6mm, 8mm, 10mm, 12mm ring spacing)  Rat 1.9F  1.6F 45 cm (18 in)
72-9113 FT312B-VSL-1/14/17/20 Rabbit VSL Pressure-Volume Catheter (11mm, 14mm, 17mm, 20mm Spacing) Rat 3F  2.7F 61 cm (24 in)
   
Control Box  
model number  Product
72-9148 / FV896B Pressure-Volume Control Box (Electronic Calibration)
72-9149 / FV898B Pressure-Volume Control Box (Adjustable Gain, Variable Segment Length Catheters)
72-9150 / FV992B Multi-Segment Pressure-Volume Control Box 
72-9151 / FV992B-R Multi-Segment Pressure-Volume Control Box (Includes Rodent Catheter Option)   
   
Acessories  
model number  Product
72-9152 / FR882B Calibration Cuvette Mouse/Rat
72-9153 / FR382B Calibration Cuvette VSL catheters
72-9154 / FR982B Calibration Cuvette 3F, 5F,7F multi-segment PV catheters
72-9155 / AMB-2053 Conductivity Meter (Includes Dip Cell and Cell Cup)


HUGO SACHS ELEKTRONIK-HARVARD APPARATUS GmbH
Gruenstrasse 1 · D-79232 March-Hugstetten · GERMANY