Force Transducer for PowerLab
The MLT0201 Force Transducer is used for measuring forces under isometric conditions in the range of 5 mg to 25 g wt. The transducer is suitable for connection to all ADInstruments Bridge Amps.
The MLT0201 Force Transducer is used for measuring forces under isometric conditions in the range of 5 mg to 25 g wt. The transducer is suitable for connection to all ADInstruments Bridge Amps.
Operation
Mount the transducer by inserting the support rod through the hole on a micropositioner or clamp and connect it to an 8-pin DIN input on the front of a Bridge Amp. Take the thread tied to the tissue and attach it to the transducer by tying a loop around the cleft in the double plate on the end of the detecting rod which protrudes from the end of the transducer body. Using the micropositioner or clamp, adjust the tension in the thread to provide the desired amount of pre-load tension on the tissue.
Application:
The MLT0201 Force Transducer is ideal for isolated tissue studies and has been designed for operation with our range of organ bath models. (For use with Radnoti Organ Baths order the MLT0201/RAD).
Mount the transducer by inserting the support rod through the hole on a micropositioner or clamp and connect it to an 8-pin DIN input on the front of a Bridge Amp. Take the thread tied to the tissue and attach it to the transducer by tying a loop around the cleft in the double plate on the end of the detecting rod which protrudes from the end of the transducer body. Using the micropositioner or clamp, adjust the tension in the thread to provide the desired amount of pre-load tension on the tissue.
Application:
The MLT0201 Force Transducer is ideal for isolated tissue studies and has been designed for operation with our range of organ bath models. (For use with Radnoti Organ Baths order the MLT0201/RAD).
Specifications | 77-0118 |
---|---|
Amplification Input Amplifier | See product page for complete specifications |
Body Diameter English | 1.2 in |
Body Diameter Metric | 30 mm |
Body Length English | 2.4 in |
Body Length Metric | 60 mm |
Bridge Resistance | 360 Ω |
Cable Length English | 6.6 ft |
Cable Length Metric | 2 m |
Connector | 8-pin DIN |
Displacement Range | ±0.45 mm |
Excitation | 5 to 10 V DC |
Model | MLT0201 |
Non linearity and Hysteresis | <1 % |
Operating Range | 5 mg to 25 g wt |
Package | 1 |
Product Family | Data Acquisition |
Resolution | 2 mg |
Resonant Frequency | 140 Hz (Typical) |
Sensitivity | (full range) 30 mV/V |
Support Rod Diameter Metric | 0.24 in |
Support Rod Length Metric | 6.3 in |
Weight | 170 g |