harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

Linear Pneumotachometer, Heated

SKU
pneumotachheated

These Linear Pneumotachometers have a special screen design which assures a linear signal over a range of flow rates and have minimum dead space.

  • For use with Differential Pressure Transducers
  • Available heated or non-heated 

For Non-Heated Pneumotachometers please see: Non-Heated Pneumotachometers

Grouped product items
Item No. Description Qty
72-6310 Heated Linear Pneumotachometer with Luer side port for airway pressure, 0 to 160 L/min flow rate, dead space 13.87 ml. Port OD = 22 mm, ID = 15 mm. Opposite port: OD 15 mm, ID = 13.2 mm. Requires heater controller. Please login to add to Quote

A pneumotachometer converts the flow of gases through it into a proportional signal of pressure difference on either side of a central screen. These Linear Pneumotachometers have a special screen design which assures a linear signal over a range of flow rates and have minimum dead space.

  • For use with Differential Pressure Transducers
  • Available heated or non-heated

The Heated Pneumotachometers require a Heater Controller and are recommended when condensation of water vapor occurs. The heater shell is removable if heating is not required. Two Heater Controllers are available to heat one or two Pneumotachometers. The cable from the Pneumotachometer heater shell connects to the rear panel of the Controller.

Both the Heated and Unheated Pneumotachometers are linear and bidirectional (produce signals for gas flow in either direction). They are available in seven flow ranges.

All Pneumotachometers are supplied with calibration curves. Adapter diameters measuring 7.5, 10.5, 15 or 22 mm are standard medical tapers. All other connectors are straight. When selecting a Pneumotachometer it is important to select the appropriate adapter size and style to match existing equipment.

For Non-Heated Pneumotachometers please see: Non-Heated Pneumotachometers

Item            

DP input to
transducer signal
pressure(mm/H2O)

Dead space
volume (ml)

Flow range
(L/min)
 

Recommended differential
pressure transducer 

Species                
59-9325  10  0.30  0 to 3   600349 or 600350  Mouse 
59-9322  10  0.39  0 to 3
 600349 or 600350
 Mouse 
59-9331  8  0.59  0 to 5 
 600348 or 600349  Mouse / Rat
59-9328  8  0.71  0 to 5   600348 or 600349
 Guinea Pig 
59-9337  10  1.06  0 to 10   600349 or 600350  Cat
59-9334  10  1.30  0 to 10 
 600349 or 600350
 Cat 
59-9340  7  1.66  0 to 10 
 600348 or 600349
 Rabbit 
59-9346  7  2.65  0 to 10 
 600348 or 600349
 Rabbit 
59-9349  7  3.28  0 to 10 
 600348 or 600349
 Rabbit 
59-9343  7  5.06  0 to 10 
 600348 or 600349
 Rabbit 
59-9352  7  6.81  0 to 35  600348 or 600349
 Small Dog 
59-9355  7  8.74  0 to 35
 600348 or 600349
 Small Dog
59-9358  7  11.45  0 to 35
 600348 or 600349
 Small Dog 
59-9361  10  18.15  0 to 100
 600348 or 600349
 Medium Dog 
59-9367  16  13.87  0 to 160  600350  Large Dog 
59-9364  16  14.18  0 to 160  600350  Large Dog 