harvardapparatus.com is a data controller for the purposes of the General Data Protection Regulation ("GDPR"). By proceeding to tick the consent box at right, you consent to harvardbioscience.com processing your personal data, under the GDPR and any other applicable legislation, that we collect from you in accordance with our Privacy Policy. If you wish to withdraw your consent for us to process your personal data please contact our Compliance Team. Please address any questions, comments and requests (including your right to withdraw your consent to process your personal data) regarding our data processing practices to our Compliance Team.
Allow

PLUGSYS Electrocardiogram (ECG) Amplifier Module (ECGA)

SKU
e85b6c02
Amplifies ECG signals up to 1,000 beats per minute
Grouped product items
Item No. Description Qty
73-0149 Electrocardiogram (ECG) Amplifer Module (ECGA) Please login to add to Quote
73-1494 ECG Cable with Needles for ECGA or BPA (Rodents) Please login to add to Quote

The Electrocardiogram (ECG) Amplifier Module (ECGA) amplifies ECG signals. A floating input circuit is used to avoid hum and grounding problems. A bar graph display permits visualization of the ECG signal. The filters are for heart rates up to 1000 beats per minute. Both outputs can be used for recording on a chart recorder or for data acquisition. A square-wave signal generator with amplitudes of 0.3 mV and 1 mV is incorporated for calibration.

Can be used with the PLUGSYS R-Wave Trigger Module.

Specifications73-0149
CalibrationSquare-wave signal generator with amplitudes of 0.3 mV and 1 mV
Commond Mode Rejection106 dB
ConnectorDIN 41612, 96-pin VG
DisplayBar graph 0.75 V/LED
Filter Indicationby green LEDs on front panel
Gain Trimmer in Position x0.5Switch in Position x0.5 1000 to 5000
Gain Trimmer in Position x1Switch in Position x1 2000 to 10000
Gain Trimmer in Position x2Switch in Position x2 4000 to 20000
High-Pass Filter(LOW CUT OFF) 5 Hz, 1 Hz, 0.5 Hz, 0.1 Hz
InputFloating differential input, isolated barrier internally clamped to 300 V, with protection against static discharges and 10 kHz input filter for h.f. suppression
Input Connector5-pin binder socket with screw lock; pin connections correspond to those of standard 3-pin ECG input cable
Input Impedance1010Ω
Low-Pass Filter(HIGH CUT OFF) 150 Hz, 120 Hz, 100 Hz, 50 Hz
OutputBNC connector on front panel (
PLUGSYS Width2 slot units
Power Supply5 V/600 mA, through connector from PLUGSYS bus system
Quick StartFor rapid discharge of coupling capacitors by pressing QUICK START key
Recorder OutputInternal output is connected to bus system via jumpers; ECG signal is connected to recorder via Recorder Output Module (ROM); also possible to connect recorder directly to BNC connector 'ECG OUT' at front panel